Basic Info
  • Model NO.: ST3PF
  • Usage: Timer Switch
  • Theory: Digital
  • Carry Base: Module-n Synchronous Counter
  • PLC Type: SE PLC
  • Model Number: Dh48s
  • Operating Voltage: 90%~110% of Rated Supply Voltage
  • Control Output: 5A220VAC
  • Operating Temperature: -10°c~50°c
  • Life: Mech:107 Elec:103
  • Specification: CE
  • HS Code: 8536410000
  • Type: Timer
  • Function: Addition Counter
  • Carry Mode: Synchronous Counter
  • Mechanism: Electronic
  • Brand Name: Suntree/OEM
  • Supply Voltage: 12/24VDC,24/110/220/380VAC
  • Power Expend: DC1.0W AC1.0va
  • Dielectric Strength: Bcc1500VAC Boc1000VAC
  • Huminity: 35%~85%
  • Trademark: suntree/oem
  • Origin: Zhejiang
Product Description
AC 110V delay timer time relay super timer relay ST3PF 12V

Time switch relay ST3Pseries time relay is used professional manufacturing technology to produce
innovative time relay, with small size, light weight, delay a wide range of anti-interference ability,
long life characteristics to be suitable for a variety of demanding precision, high reliability,
automation and control sites used for delay control.

Normal operating conditions and installation conditions
1, Use of the environment: the altitude not exceeding 2,000 m; around the attack is not higher
than +40 ambient temperature and not lower than -5 ; supply voltage range of 85% -110% rated voltage;
in the absence of severe shock and explosion medium risk and medium non-corrosive metal
and undermine the insulation is sufficient gas and dust; in the absence of rain and snow in places;
2, Vertical or horizontal installation.

Technical features
1 Repeat error: less than 2.5%
2 Contact capacity: AC 250V, 1A
3 Operation Voltage: 36V, 110V, 127V, 220V, 380V, DC: 24V ;
4 Mechanical life: greater than or equal to 100 million times;
5 Electrical life: greater than or equal to 10 million times;
6 Power consumption: less than or equal to 1.5W;
7 Delaying precision <5%;
8 Delaying specification: 1s 5s 10s 30s 60s 120s 180s 10m

ST3P Series Time Relay Multi-file type specification has a different delay profile,
you can at the same time the front of the relay switch is easily converted.
When you need to change delay file, first remove the setting knob, then remove
the scale plate, and then refer to nameplate on the schematic drawing of the delay range of
dynamic change-over switch, and then scale as is loaded on
board and set the knob, switch position should be marked with the scale on-board switch
position is consistent.

Notes
The use of relay operating voltage should be rated operating voltage range.
Greater than the rated load power relays, please add the middle relay.

Transport and storage:
Product storage and dynamic inputs are not subject to rain and snow during the invasion,
should be placed in storage in the air circulation, relative humidity (25 ± 5 ) does not
exceed 90%. The temperature limit of -5 , the temperature limit of +40.

CLASSIFICATIONTIMER
MODELST3P
DIMENSIONS50H*40W*57.5D
MOUNTING&SOCKERSURFACE(-N)PF083A-E
FLUSH(-Y)US-08  P3G-08
FULL TIMING RANGEA:0.05 - 0.5s/5s/30s/3min
B:0.01-1s/10s/60s/6min
C:0.5-5s/50s/5min/30min
D:1-10s/100s/100m/60m
E:5s-60m/10m/60m/6h
F:0.25-2min/20min/2h/12h
G:0.5-4min/40min/4h/24h
RATED VOLTAGEAC(V):24 - 220 DC(V):24 - 110(50/60Hz)
INDICATOR OPERATINGON-UP Operating
O/P CONTACTMODELST3PAST3PC
TIME LIMIT 1C-5A
TIME LIMIT 2C5A-
INSTANTENOUS 1C-5A
LIFEMECHANICAL5*10 7 times
ELECTRICAL10 5 times
ACCURACYREPEA ERROR±2% max
SETTING ERROR±5% max
VOLTAGE ERROR±5% max
TEMP.ERROR±2% max
RESET TIME0.5 sec max
CONSUMED POWER2VA
AMBIENT TEMPERATURE-10ºC~+55ºC
AMBENT HUMINITY35~85%RH
WEIGHT100g

ClassificationTimer Relay
Specification/ ModelST3PFST3PKST3PYST3PR
Dimension55H × 40.5W × 57.5D55H × 40.5W × 57.5D55H × 40.5W × 57.5D55H × 40.5W × 57.5D
FunctionOff delayBreaking delayDelaying of star-delta starterOn-off delaying repetitive
Delaying Accuracy1%1%0.5%±10ms1%
Contact AmountTimed 1 SpdtTimed 1 SpdtTimed star-delta transfer Inst.1 normally openTimed 1 Spdt
Contact CapacityAC220V 3AAC220V 3AAC220V 3AAC220V 2A
Delaying Range0.1~1s 0.2~2s 0.5~5s
1~10s 2.5~30s 5~60s
0.1~1s 0.25~2s 0.5~5s
1~10s 2.5~30s 5~60s
15~180s
1~10s 2.5~30s 5~60s0.5~6s/60s 1~10s/10min 2.5~30s/30min
Rated VoltageAC110, 220V
DC24, 48, 110V
AC110, 220V
DC24V
AC110, 220VAC110, 220V DC24V





1. AH3-3 time relay Application

AH3-3 series time relay is used ASIC and professional manufacturing technology to produce
innovative time relay, with small size, light weight, delay a wide range of anti-interference ability,
long life characteristics to be suitable for a variety of demanding precision, high reliability,
automation and control sites used for delay control .

2. AH3-3 time relay Specifications and parameters
ClassificationMulti Range TimerMulti Range TimerMulti Range Timer
Specification ModelAH3-3AH3-BAH3-NB
Dimension50H × 40W × 57.5D50H × 40W × 57.5D50H × 40W × 57.5D
Mounting & SocketSurface(-N)PF083A (E)PF083A (E)PF083A (E)
Flush(-Y)US-08 P3G-08US-08 P3G-08US-08 P3G-08
Full Timing RangeSEC:1,3,6,10,12,30,60
MIN:3,6,10,12,30,60
HR:3,6,10,12,30
A:1S,10S,1M,10M
B:3S,30S,3M,30M
C:6S,60S,6M,60M
D:1M,10M,1H,10H
E:3M,30M,3H,30H
A:1S,10S,1M,10M
B:3S,30S,3M,30M
C:6S,60S,6M,60M
D:1M,10M,1H,10H
E:3M,30M,3H,30H
Rated Voltage (V)AC: 24,110,220,240,380,50/60Hz
DC: 12,24
AC: 24,110,220,240,380,50/60Hz
DC: 12,24
AC: 24,110,220,240,380,50/60Hz
DC: 12,24
Indicator OperatingON-UP operatingON-UP operatingTime operating flicker
O/P ContactModelAH3-1AH3-2AH3-3AH3-1AH3-2AH3-3Model A/B
Time Limit 1C5A
 
5A
 

 
5A
 
5A
Time Limit 2C
 
5A
 
5A
 

 
5A
 
Instantaneous 1C
 

 
5A
 
5A5A
 
5A
LifeMechanical5×106 Times5×106 Times5×106 Times
Electrical105 Times105 Times105 Times
AccuracyRepeat Error±1% max±1% max±1% max
Setting Error±10% max±10% max±10% max
Voltage Error±1% max±1% max±1% max
Temp Error±2% max±2% max±2% max
Reset Time0.1 sec max0.1 sec max0.1 sec max
Consumed Power3VAC3VAC3VAC
Ambient temperature-10oC~+55oC-10oC~+55oC-10oC~+55oC
Ambient Huminity48~85% RH48~85% RH48~85% RH
Weight160g160g160g

3. AH3-3 time relay Normal operating conditions and installation conditions:
3.1 The use of the environment: the sea disturbance height of not more than 2000 meters,
ambient temperature is not higher than +40 and no less than -5 ; supply voltage range of 85%
-110% rated voltage; in the absence of a serious shock and explosion hazard medium,
and medium, non-corrosive metal and undermine the insulation is
sufficient gas and dust; in less rain and snow hit areas.
3.2 vertical or horizontal installation.
Technical features
1, supply voltage: AC (50Hz) 24V, 36V, 110V, 127V, 220V, 380V; DC: 24V (other voltages can
be customized);
2, electrical life: ≥ 10 × 104 times;
3, Mechanical life: ≥ 100 × 104 times;
4, contact capacity: AC220V 3A; DC220V 0.5A COSφ = 1;
5, use the Class: AC-15 DC-13;
6, repeated the error: "1%;
7, reset time: ≤ 1 sec;
8, power consumption: ≤ 1.5W (DH11S ≤ 3W).






DH48S Digital display time relay is used in the scale of the advanced application specific integrated circuit, LED digital tube display, beautiful appearance, easy installation, digital key switch preset, stable and reliable, high precision, delay range, low power consumption advantages, is widely used in automatic control circuits for delay device.



1. Timing Range:
H:1min-99h99min
M:1s-99min99s
S:0.01s-99.99s
Normal operating conditions and installation conditions
1.1 The use of the environment: the sea disturbance height of not more than 2000 meters, ambient temperature is not higher than +40 and no less than -5 ; supply voltage range of 85% -110% rated voltage; in the absence of a serious shock and explosion hazard medium, and medium, non-corrosive metal and undermine the insulation is sufficient gas and dust; in less rain and snow hit areas.
1.2 Vertical or horizontal installation.

2.1 Technical Features:
1, supply voltage: AC (50Hz) 24V, 36V, 110V, 127V, 220V, 380V; DC: 24V (other voltages can be customized);
2, electrical life: ≥ 10 × 104 times;
3, Mechanical life: ≥ 100 × 104 times;
4, contact capacity: AC220V 3A; DC220V 0.5A COSφ = 1;
5, use the Class: AC-15 DC-13;
6, repeated the error: "1%;
7, reset time: ≤ 1 sec;
8, power consumption: ≤ 1.5W (DH11S ≤ 3W).


Products Specification:


Part number
DH48S-ADH48S-AEDH48S-2ZDH48S-1ZDH48S-EDH48S-S/2ZDH48S-S/1Z
Indicators8 mm LED numeric display
Supply voltageAC24V,110V,220V,380V 50/60Hz DC12V,24V
Operating voltage85 to 110% of rated supply voltage(90% to 110% at 12 VDC)
Power consumption≤5W
Control  outputTime limitSPDT(2C)SPDT(2C)SPDT(2C)SPDT(1C)SPDT(1C)SPDT(2C)SPDT(1C)
Instantaneous
 
SPDT(1C)
 

 
SPDT(1C)
 

 
Output Max.Load5A,250VAC(p.f=1)
Output Min.Load10 mA,5 VDC
Input     methodReset inputno-voltage unput
Impedance at short-circuit:max.1kΩ
Impedance at open:min.100kΩ
residual voltage at short-circuit:max.0.5V
Gate input
Repeat accuracy±0.3%,±0.05sec(includes variation due to voltage and temperature changes)
Setting error±0.5%,±0.05sec
Resetting systemPower-OFF
Resetting time0.1 sec max.
Connections11-pin round socket8-pin round socket
Mountingtrack,surface
Operating ambient temperature-10 to 55
Ambient humidity Operating35 to 85%RH
Insulation resistanceInsulation resistance 100MΩ min.at500VDC
Dielectric strength2000V 50/60Hz min between current-carring and non-current-carring parts and between contact and control circuit
1500V 50/60Hz min between control output terminals and operating circuit
1000V 50/60Hz min Between contacts
Static immunityMalfunction:8 KV Destruction:15KV
Impulse withstand voltage3 kV (between power terminals)1 kV for 24 DC
4.5KV(between current-carrying terminal and exposed non-current-carrying metal parts);1.5 kV for 24VDC
VibrationMechanical durability10 to 55 Hz with 0.75-mm double amplitude each in 3 directions
Malfunction durability10 to 55 Hz with 0.5-mm double amplitude each in 3 directions
ShockMechanical durability30G
Malfunction durability10G
Service lifeMechanical10 million operations minimum(under no load, at 1,800 operations/hour)
Electrical100,000 operations minmum at maximum ratings
Degree of protectionTECIP30(panel surface)
WeightApprox:150g



 
Send your message to this supplier
Avatar
Miss cara
manager
*From:
To: Miss cara
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category