Gold Member Since 2007
Audited Supplier
Xinchi Electric Co., Ltd.

Power Meter, Digital Electric Meter, Electric Meter manufacturer / supplier in China, offering DIN Rail Three Phase Power Meter Digital Electric Meter Electric Meter, Suntree Hot Sale Solar Inverter 10000 Watts for Solar System, 4p 1200V PV Solar System DC Isolator Switch and so on.

(/ )

Supplier Homepage Product Other Electrical Products DIN Rail Three Phase Power Meter Digital Electric Meter Electric Meter

DIN Rail Three Phase Power Meter Digital Electric Meter Electric Meter

FOB Price: Get Latest Price
Min. Order: 50 Pieces
Production Capacity: 1000PCS/Week
Transport Package: Formal
Payment Terms: T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: DDS
  • Installation: DIN Rail
  • Electric Equipment: Single-phase
  • Power Meter Connection: Terminal
  • Type: Energy Meter
  • Customized: Customized
  • Model Number: Electricity Meter
  • Measuring Range: 20A 25A 30A 40A 60A 80A 100A
  • Supply Voltage: 220V-360V AC
  • Phase: Single Phase or Three Phase
  • Isntallation: 35mm
  • Specification: CE
  • Display: Digital
  • Usage: Multi-Functional Energy Meter, Standard Electric Energy Meter
  • Theory: Electronic Meter
  • Measured Signal: Continuous Wave
  • Certification: RoHS, CE
  • Brand Name: Suntree/OEM
  • Display Type: Digital Only
  • Accuracy Class: 1.0
  • Operating Temperature: -25--+55
  • Measure: V, a, Kw, Cos, Hz,
  • Trademark: SUNTREE/oem
  • Origin: Zhejiang Wenzhou
Product Description

DIN rail three phase power meter digital electric meter electric meter

 Single-phase Two-wire Electronic DIN-rail Active Energy Meter (1Pole, LCD Display)


APPLICATION
single phase two wire electronic DIN-rail active energy meter.
The meter is used to measure 50Hz or 60Hz active energy consumption from single phase two wire AC electricity net. 
The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and 
small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro,etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation or front board setting, complying with standard DIN EN50022.
one pole width.
LCD 6+1 digits display (999999.1kWh) by without backlight source common LCD.May select white backlight   source LCD display, or clients defined.
Standard configuration one port of pulse output passive (polarity),complying with standard IEC62053-31 and DIN43864.
Single direction measures single phase two wire active power consumption. It is nothing with direction of the flow of load current, complying with standard IEC62053-21,IEC62052-11.
Adopts high reliable and long-life electric components, high overload, do not need to calibrate for long-term operation.
Directly connect operation.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install.

 
TECHNICAL PARAMETERS 
AccuracyClass 1.0
Rated voltage220VAC, 230VAC, 240VAC, etc.
Operation voltage range  Un±20%
Insulation capabilitiesAC voltage withstand 2kV for 1 minute; Impulse voltage withstand 6kV - 1.2/50μs waveform.
Rated current range5(20)A , 5(25)A , 5(30)A,5(32)A,etc.
Operation current range0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency50Hz or 60 Hz
Internal power consumptionVoltage circuit ≤1.0W 5VA; Current circuit ≤1VA(Ib)
Impulse valence Ra0,5 or 1.0 Wh/imp 
InterfaceOptical coupler (SO corresponding to DIN43864)
Max.operation temperature-40°C ~ +80°C 
Max.storage temperature-45°C ~ +85°C
Relative humidity≤85
Dimension17.5mm * 76.5mm * 90mm     
WeightApprox. 90g
*Please advise us if you need any different specifications,we can make according to your special requirements.



DIN Rail Three Phase Power Meter Digital Electric Meter Electric Meter
Three-phase Three-wire Electronic DIN-rail Active Energy Meter (7-Pole, Cyclometer Display)

APPLICATION
three phase three wire electronic DIN-rail active energy meter,cyclometer display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase three wire AC electricity net.
The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro, etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven poles width.
Cyclometer 5+1 digits display (99999.9kWh),may select 6+1 digits (999999.9kWh)display.
Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive   
(nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates respectively power-supply,impulse,and communication,etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase three wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover.

 
TECHNICAL PARAMETERS
AccuracyClass 1.0
Rated voltage(VAC)3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilitiesAC voltage withstand 2kV for 1 minute;Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A)1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency50Hz or 60Hz
Internal power consumptionVoltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra0.5 or 1.0 Wh/imp
Interfaceoptical coupler (SO corresponding to DIN 43864)
Temperature RangeNormal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity≤ 85%
Service LifeMore than 10 years
Dimension125mm x 88mm x 73mm
WeightApprox 650g
*Please advise us if you need any different specifications, we can make according to your special requirements.

 



Three-phase Three-wire Electronic DIN-rail Active Energy Meter (7-Pole, LCD Display)
APPLICATION
 three phase three wire electronic DIN-rail active energy meter,LCD display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net.
The features of small size & DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro,etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven poles width.
 LCD 6+1 or 5+2 display without backlighting;May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off.
Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates respectively power-supply,impulse,and communication,etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase three wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover.

 
TECHNICAL PARAMETERS
AccuracyClass 1.0
Rated voltage(VAC)3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilitiesAC voltage withstand 2kV for 1 minute;Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A)1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency50Hz or 60Hz
Internal power consumptionVoltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra0.5 or 1.0 Wh/imp
Interfaceoptical coupler (SO corresponding to DIN 43864)
Temperature RangeNormal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity≤ 85%
Service LifeMore than 10 years
Dimension125mm x 88mm x 73mm
WeightApprox 650g
*Please advise us if you need any different specifications,we can make according to your special requirements.


Three-phase Four-wire Electronic DIN-rail Active Energy Meter (7-Pole, Cyclometer Display)
APPLICATION
three phase four wire electronic DIN-rail active energy meter, cyclometer display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net.
The features of small size and DIN-rail mounting make it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings, shopping malls, residences, airports and metro, etc.

 
FUNCTIONS AND FEATURES
35mm standard DIN rail installation,complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven-pole width.
Cyclometer 5+1 digits display (99999.9kWh),may select 6+1 digits display.
?Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates phase, impulse, reverse, etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase four wire active energy consumption. It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
May select two components measure three phase three wire active energy or two phase three wire active energy.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover,which is helpful to reduce installation space and make it convenient to install;May select extended terminal cover.

 
TECHNICAL PARAMETERS
AccuracyClass 1.0
Rated voltage(VAC)3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilitiesAC voltage withstand 2kV for 1 minute;Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A)1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency50Hz or 60Hz
Internal power consumptionVoltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra0.5 or 1.0 Wh/imp
Interfaceoptical coupler (SO corresponding to DIN 43864)
Temperature RangeNormal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity≤ 85%
Service LifeMore than 10 years
Dimension125mm x 88mm x 73mm
WeightApprox 650g
*Please advise us if you need any different specifications, we can make according to your special requirements.



Three-phase Four-wire Electronic DIN-rail Active Energy Meter (7-Pole, LCD Display)
APPLICATION 
three phase four wire electronic DIN-rail active energy meter,LCD display.
The meter is used to measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net.
The features of small size & DIN-rail mounting makes it suitable for installation in distribution boards and small standard enclosures.
The meter is widely used in the office buildings,shopping malls,residences,airports and metro,etc.
 

 
 
FUNCTIONS AND FEATURES 
35mm standard DIN rail installation,complying with standard DIN EN50022.Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
Seven poles width.
LCD 6+1 or 5+2 display without backlighting;May select with white backlighting, and there is maintenance-free battery used for display when the power-supply cut off.
Standard configuration one port of pulse output passive (polarity),may select increase a distant port of pulse output passive (nonpolarity),complying with standard IEC62053-31 and DIN 43864.
LED indicates phase-line,impulse,reverse,etc.
Automatically detect the direction of the trend of load current. If the LED "REV" lights that means the load current is reverse.
Single direction three components measure three phase four wire active energy consumption.It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11.
May select two components measure three phase three wire active energy or two phase three wire active energy.
Direct connect operation or through CT or PT & CT.
Standard configuration short terminal cover, which is helpful to reduce installation space and make it convenient to install; May select extended terminal cover.
 

 
 
TECHNICAL PARAMETERS 
AccuracyClass 1.0
Rated voltage(VAC)3*57.5/110,  3*110/200,  3*220/380,  3*230/400,  3*240/415,etc.
Operation voltage range Un±20%
Insulation capabilitiesAC voltage withstand 2kV for 1 minute;
Impulse voltage withstand 6kV - 1.2/50μs waveform
Rated current(A)1.5(6), 5(30), 10(60), 20(80), 30(100),etc.
Operation current range0.05Ib~ Imax
Starting current 0.004Ib
Rated frequency50Hz or 60Hz
Internal power consumptionVoltage circuit ≤1.0W 5VA;   Current circuit ≤1VA(Ib)
Impulse valence Ra0.5 or 1.0 Wh/imp
Interfaceoptical coupler (SO corresponding to DIN 43864)
Temperature RangeNormal operation temperature: -35ºC--+70ºC
Extreme operation temperature: -40ºC--+75ºC
Storage Temperature: -45ºC--+85ºC
Relative humidity≤ 85%
Service LifeMore than 10 years
Dimension125mm x 88mm x 73mm
WeightApprox 650g
*Please advise us if you need any different specifications,we can make according to your special requirements.




SINGLE PHASE TWO WIRE DIN-RAIL WATT-HOUR METER
DIN Rail Three Phase Power Meter Digital Electric Meter Electric Meter



THREE PHASE FOURWIRE DIN-RAILWATT-HOUR METER
DIN Rail Three Phase Power Meter Digital Electric Meter Electric Meter
Send your message to this supplier
Avatar
Miss cara
manager
*From:
To: Miss cara
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now